NEW QUESTION # 50
Which of the following makes the biggest impression on a customer when you are communicating via email?
- A. Tone of voice
- B. Body language
- C. Choice of words
Answer: C
NEW QUESTION # 51
A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______?
- A. 15 m (50')
- B. 30 m (100')
- C. 10 m (33')
- D. 5 m (16.5')
Answer: C
NEW QUESTION # 52
What is the size of a rack-mounted unit (RMU)?
- A. 38 mm (1.5")
- B. 45 mm (1.75")
- C. 50 mm (2")
- D. 25 mm (1")
Answer: B
NEW QUESTION # 53
In an environment with high electromagnetic interference (EMI), which of the following would be the MOST critical practice to maintain cable performance?
- A. Using plenum cable instead of riser cable for better EMI resistance
- B. Maintaining the cable's overall foil or braid shield continuity and using grounded metallic pathways
- C. Installing additional twisting on each pair of the cable to improve cross-talk immunity
- D. Ensuring slack loops of at least 3 m (10 ft) are present in each outlet space
Answer: B
NEW QUESTION # 54
Which of the following is a property of an electromagnetic field built around a conductor that opposes any changes in current flow in a circuit?
- A. Inductance
- B. Impedance
- C. Resistance
- D. Capacitance
Answer: A
NEW QUESTION # 55
Which of the following steps should be performed first when an installer is pulling optical fiber cable?
- A. Ensure the cable has been tested and accepted
- B. Install and secure innerduct
- C. Attach pull rope
- D. Label cables
Answer: A
NEW QUESTION # 56
Which of the following is used to perform continuity and length tests for coaxial cable?
- A. VFL (visual fault locator)
- B. TDR (Time domain reflectometer) with an adapter
- C. OLTS (optical loss test set)
- D. OTDR (optical time domain reflectometer
Answer: B
NEW QUESTION # 57
What is the primary purpose of the telecommunications bonding infrastructure?
- A. Equalize potentials between metallic surfaces and equipment within entrance facilities
- B. Provide backup power to the telecommunications equipment when primary power to the equipment fails.
- C. Improve the performance of the installed telecommunications equipment
Answer: A
NEW QUESTION # 58
When performing an OTDR test on a multimode fiber, which of the following events indicates a likely macrobend?
- A. A gradual loss over the full distance of the fiber
- B. A reflection at the far end with minimal insertion loss
- C. A sudden spike with a large positive reflection
- D. A sharp drop in backscatter in a localized section of the trace
Answer: D
NEW QUESTION # 59
What is the MOST likely negative consequence of not maintaining proper cable slack in the TR (e.g., 3 m / 10 ft) as recommended by BICSI?
- A. Increased crosstalk on the link
- B. Blocking patch cord access in the rack
- C. Violation of local electrical building codes
- D. Inability to re-terminate or move cabling in the future
Answer: D
NEW QUESTION # 60
Which of the following is a measure of the amount of information being transported over media?
- A. Megahertz
- B. Megabits
- C. Kilowatt hours
- D. Volt-amperes
Answer: B
NEW QUESTION # 61
A third 90-degree bend may be permitted in a conduit run if one of the bends is located within ____ of the cable feed end?
- A. 375 mm (15")
- B. 450 mm (18")
- C. 300 mm (12")
- D. 483mm (19")
Answer: C
NEW QUESTION # 62
When specifying cable routing within an Equipment Room (ER), BICSI guidelines recommend that ladder racks be mounted with adequate clearance from the top of the equipment racks. What is the TYPICAL recommended vertical clearance?
- A. 45 cm (18 in)
- B. 30 cm (12 in)
- C. 60 cm (24 in)
- D. 15 cm (6 in)
Answer: B
NEW QUESTION # 63
Which pair of a 100-ohm balanced twisted pair patch cable has a white-brown tip and a brown-white ring?
- A. Pair 3
- B. Pair 2
- C. Pair 4
- D. Pair 1
Answer: C
NEW QUESTION # 64
During a fiber optic cable installation, the cable manufacturer specifies a maximum tensile load of 2700 N (600 lb). What is the TYPICAL recommended maximum pulling tension you should not exceed for short pulls, to ensure safety margins?
- A. 1350 N (300 lb)
- B. 1890 N (425 lb)
- C. 810 N (180 lb)
- D. 2700 N (600 lb)
Answer: A
NEW QUESTION # 65
......